Ductile Iron Fisher Gas Regulator 627 Model Pressure Gas Regulator

Brand Name : Fisher
Model Number : 627-1217-29855(old model 627-496)
Place of Origin : Made In China
MOQ : Negotiation
Price : Negotiation
Payment Terms : T/T, Western Union, MoneyGram
Supply Ability : 500sets Every Month
Delivery Time : 3 work-days
Packaging Details : 1set packed in one carton ,each carton size is 29*18*18cm,3kg/set.
Name : Fisher 627 Pressure Gas Regulator Use for LPG
End Connetion : 1" NPT
Inlet Pressure : 250psi/17.2Bar
Outlet Pressure : 5-20psi
Body Material : Ductile Iron
Orifice Size : 1/2"
Contact Now

Fisher Original 627-496(627-1217-29855) Pressure Gas Regulator


Features

Internal Relief Valve

Relief Operation Indicator

Easy to Maintain

Installation Adaptability

Application Versatility

Tamper-Resistant

Wide Range of Flow Capabilities


Description

Fisher 627 Series self-operated pressure reducing regulators (Figure 1) are for high and low pressure systems. Fisher 627 regulators can be used with natural gas, air, or a variety of other gases. Performance characteristics vary according to construction.


The Specifications section gives some general specifications for Fisher 627 Series regulators. The nameplates (Figure 2) give detailed information for a particular regulator as it comes from the factory.


Table 1. Maximum Inlet Pressures,Outlet Pressure Ranges

TYPEOUTLET PRESSURE RANGEORIFICE SIZE,
INCHES (mm)
MAXIMUM INLET PRESSURE, PSIG (bar)
6275 to 20 psig
(0.34 to 1.38 bar)
1/2 (12.7)250 (17.2)
15 to 40 psig
(1.03 to 2.76 bar)
1/2 (12.7)300 (20.7)
35 to 80 psig
(2.41 to 5.52 bar)
1/2 (12.7)750 (51.7)
70 to 150 psig
(4.83 to 10.3 bar)
1/2 (12.7)750 (51.7)

Specifications

1” NPT End Connection : 627-496,627-497,627-498,627-499

2” NPT End Connection:627-576,627-577,627-578,627-579


Available Constructions

Type 627: Self-operated pressure reducing regulator equipped with a pitot tube for greater regulated capacities (Figure 7).

Type 627R: Type 627 with internal relief and with an open throat (Figure 8).

Type 627M: Type 627 with a stem seal between the body outlet pressure and diaphragm case. Pressure is measured under the diaphragm through the 1/4-inch NPT downstream control line connection (Figure 9).

Type 627MR: Type 627M with internal relief (Figure 10).

Type 627H: Type 627 with a diaphragm limiter to deliver a higher outlet pressure (Figure 11).

Type 627HM: Type 627H with a stem seal between the body outlet pressure and diaphragm case. Pressure is measured under the diaphragm through two 1/4-inch NPT downstream control line connections (Figure 12).

Body Sizes

1, or 2-inch

End Connection Styles

3/4, 1, or 2-inch body sizes: NPT

1 or 2-inch (DN 25 or 50) body sizes:

ANSI Class 300 or 600 RF flanged

Maximum Inlet Pressure(1) (Body Rating)

2000 psig (138 bar) for NPT steel, 1480 psig

(102 bar) for RF flanged steel, or 1000 psig (69 bar) for ductile iron

Maximum Valve Disk Inlet Pressure Rating(1)

2000 psig (138 bar) for nylon disk or 1000 psig

(69 bar) for nitrile disk

Pressure Registration
Type 627, 627H or 627R: Internal


Installation

Regulator operation within ratings does not preclude the possibility of damage from debris in the lines or from external sources. A regulator should be inspected for damage periodically and after any overpressure condition. Like most regulators, 627 Series regulators have outlet pressure ratings that are lower than their inlet pressure ratings. A pressure-relieving or pressure-limiting device must be provided by the user for the Types 627, 627H, 627M, and 627HM regulators if the inlet pressure can exceed the outlet pressure rating, since these regulators do not have internal relief.

Type 627R regulators provide internal relief which limits the total outlet pressure buildup over setpoint. Use Table 3 to determine the total outlet pressure. This internal relief may be adequate for the application, if not, provide additional pressure relief or a pressure-limiting device downstream.


WARNING

A regulator may vent some gas to the atmosphere. In hazardous or flammable gas service, vented gas may accumulate and cause personal injury, death, or property damage due to fire or explosion. Vent a regulator in hazardous gas service to a remote, safe location away from air intakes or any hazardous area. The vent line or stack opening must be protected against condensation or clogging.




Product Tags:

fisher regulator valve

      

fisher flow control valve

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

Ductile Iron Fisher Gas Regulator 627 Model Pressure Gas Regulator Images

Inquiry Cart 0
Send your message to this supplier
 
From:
To: Suzhou Ephood Automation Equipment Co., Ltd.
Subject:
Message:
Characters Remaining: (0/3000)